Select the duty point
Provide the equipment flow requirement and circuit losses from hoses, strainers, fittings and elevation. A maximum-flow figure alone cannot establish whether a pump will serve your installation.
MARINE PUMPS · MAGNETIC DRIVE
The March LC-5C-MD is a centrifugal magnetic-drive pump without a shaft seal. It can operate submerged or outside the water with a correctly installed liquid supply. Ask PLC Marine about selection or replacement for a marine system in Mexico.
Request a quotation
| Standard configurations | 115 V or 230 V single-phase, 50/60 Hz; separate versions |
|---|---|
| 115 V reference | 0150-0004-0500 |
| 230 V reference | 0150-0004-0600 |
| Inlet | 1" FPT |
| Outlet | 1/2" MPT |
| Maximum flow at 60 Hz | 14.5 US GPM · 54.9 L/min |
| Maximum head at 60 Hz | 27 ft · 8.2 m |
| 50 Hz maximum references | 14.5 US GPM; 6 m (flow; head) |
| Installation | Submerged or open air; flooded suction |
| Maximum liquid temperature | 130 °F · 54 °C |
Reference: March manual dated August 22, 2025; data based on water. Maximum flow and maximum head are separate limits, not one simultaneous duty point. Use the curve for the circuit load.
Provide the equipment flow requirement and circuit losses from hoses, strainers, fittings and elevation. A maximum-flow figure alone cannot establish whether a pump will serve your installation.
The standard 115 V and 230 V versions have separate part numbers. Send a legible nameplate photograph and confirm the available frequency. Do not assume one unit can be connected to either voltage.
Include LC-5C-MD, the part number and photographs of the ports and mounting. LC versions and other pumps in the same series are not universal replacements. Review strainer condition, water supply and pipework as part of the inquiry.
The March marine guide includes these models for fresh, salt and seawater. Final selection must account for materials, temperature, circuit conditions and the actual liquid being pumped.
No. They are different ends of the performance curve. Determining flow in your installation requires the total circuit head and the curve for the correct frequency.
Do not assume it is dual-voltage. March lists 0150-0004-0500 for 115 V and 0150-0004-0600 for 230 V. Check the nameplate and request the correct reference.
No. The manual prohibits dry running and requires flooded suction. Installation protection and commissioning must follow the manufacturer instructions.
PLC MARINE GROUP · MÉXICO
Send the installation details to review the part number, configuration and supply conditions.
Browse all equipment for quotation →
Pricing, availability, configuration and delivery are confirmed in your quotation.

LET’S TALK
Product advice, availability or a quotation. Talk to the PLC Marine team.
+52 56 5912 4231
Chat on WhatsAppYour conversation continues in WhatsApp.